tions. Use a special cleaning agent for
glass ceramic or stainless steel.
2. Clean the appliance with a moist cloth and
some detergent.
3. At the end rub the appliance dry with a
clean cloth.
Troubleshooting
Problem Possible cause Remedy
You cannot activate or operate the
appliance.
The appliance is not connected to
an electrical supply or it is con-
nected incorrectly.
Check if the appliance is correctly
connected to the electrical supply
(refer to connection diagram).
Problem with the house electrical
system.
Examine the fuse in the electrical
system of the house in the fuse
box. If the fuses blow again and
again, speak to qualified electri-
cian.
The residual heat indicator does
not come on.
The cooking zone is not hot be-
cause it operated only for a short
time.
If the cooking zone operated suffi-
ciently long to be hot, speak to the
service centre.
If you tried the above solutions and cannot re-
pair the problem, speak to your dealer or the
Customer Care Department. Give the data from
the rating plate, three-digit-letter code for the
glass ceramic (it is in the corner of the cooking
surface) and an error message that comes on.
If you operated the appliance incorrectly, the
servicing by a customer service technician or
dealer will not be free of charge, even during
the warranty period. The instructions about the
customer service and conditions of guarantee
are in the guarantee booklet.
Installation
Warning! Refer to the Safety chapters.
Before the installation, note down the
serial number (Ser. Nr.) from the rating
plate.The rating plate of the appliance is
on its lower casing.
ZVM64N
949 594 267 01
58 PEE 11 AO
ZANUSSI
220-240V 50-60Hz
6,0 kW
Built-in appliances
Only use the built-in appliances after you as-
semble the appliance into correct built-in
units and work surfaces that align to the
standards.
Connection cable
Use the correct mains cable of type H05BB-
F Tmax 90°C (or higher) for a single phase or
two phase connection.
Replace the damaged mains cable with a
special cable (type H05BB-F Tmax 90°C or
higher). Speak to your local Service Centre.