Important safety requirements
This hob must be installed in accordance
with the Gas Safety (Installation and Use)
Regulations (Current Edition) and the IEE
Wiring Regulations (Current Edition).
For appliances installed in the Republic of
Ireland please refer to NSAI- Domestic Gas
Installation I.S. 813 Current Editions and
the ETCI Rules for Electrical Installations.
Provision for ventilation
Detailed recommendations are contained in
the following British Standards Codes Of
Practice: B.S. 6172/ B.S. 5440, Part 2 and
B.S. 6891 Current Editions.
The hob should not be installed in a bed
sitting room with a volume of less than 20
m
3
. If it is installed in a room of volume less
than 5 m
3
an air vent of effective area of 110
cm
2
is required. If it is installed in a room of
volume between 5 m
3
and 10 m
3
an air vent
of effective area of 50 cm
2
is required, while
if the volume exceeds 11 m
3
no air vent is
required. However, if the room has a door
which opens directly to the outside no air
vent is required even if the volume is between
5 m
3
and 11 m
3
.
If there are other fuel burning appliances in
the same room, B.S. 5440 Part 2 Current
Edition, should be consulted to determine
the requisite air vent requirements.
For appliances installed in the Republic of
Ireland please refer to the NSAI- Domestic
Gas Installation I.S. 813 Current Editions