The following requirements for ventilation must be
met.
The cooker should not be installed in a bed sitting
room with a volume of less than 25m
, if it is
installed in a room of volume less 5m
an air vent
of effective area of 110cm
is required; if it is
installed in a room of volume between 5m
and
10m
, an air vent of effective area 50cm
is
required, while if the volume exceeds 11m
no air
vent is required. However, if the room has a door,
which opens directly to the outside, no air vent is
required even when the volume is between 5m
and 11m
3
.
If there are other fuel burning appliances in the
same room, B.S. 5440: Part. 2: Current Editions
should be consulted to determine the requisite air
vent requirements.
Location
The cooker may be located in a kitchen, a
kitchen/diner or bed sitting room but not in a
bathroom or shower room.
For information regarding the fitting of flexible
supply pipes, the highest temperature at the rear
of this cooker which may come into contact with
the supply pipe is 70°C above ambient.
If a cooker hood is installed above this cooker it
must be a 90cm hood and installed according to
the manufacturer’s instructions.