Warning! The following instructions about
installation, maintenance and ventilation
must be carried out by qualified personnel in
compliance with the regulation in force (UNI-
CIG 7129 - 7131). Make sure that the kitchen
is well ventilated: keep natural ventilation holes
open (at least 100 cm²) or install a mechanical
extractor hood.
Gas Connection
Choose fixed connections or use a flexible pipe
in stainless steel in compliance with the regula-
tion in force. If you use flexible metallic pipes,
be careful they do not come in touch with mo-
bile parts or they are not squeezed. Also be
careful when the hob is put together with an
oven.
Important! Make sure that the gas supply
pressure of the appliance obeys the
recommended values.
If the supplied pressure has not the specified
value, it is necessary to assemble a proper
pressure regulator in compliance with the
standard UNI EN 88. For Liquid Gas (LPG) the
use of pressure regulator is allowed only if they
are in compliance with UNI EN 12864. The ad-
justable connection is fixed to the comprehen-
sive ramp by means of a threaded nut G 1/2".
Screw the parts without force, adjust the con-
nection in the necessary direction and tighten
everything.
ABC
A) End of shaft with nut
B) Washer
C) Elbow (if needed)
Rigid connection:
Carry out connection by using metal rigid pipes
(copper with mechanical end) (UNI-CIG 7129).
Flexible connection:
Use a flexible pipe in stainless steel (UNI-CIG
9891) with a maximum length 2 m.
Important! When installation is complete,
make sure that the seal of each pipe fitting is
correct. Use a soapy solution, not a flame!
Injectors replacement
1. Remove the pan supports.
2. Remove the caps and crowns of the burn-
er.
3. With a socket spanner 7 remove the injec-
tors and replace them with the ones which
are necessary for the type of gas you use
(see table in "Technical Information" chap-
ter).
4. Assemble the parts, follow the same pro-
cedure backwards.
5. Replace the rating plate (it is near the gas
supply pipe) with the one for the new type
of gas supply. You can find this plate in the
package supplied with the appliance.
If the supply gas pressure is changeable or dif-
ferent from the necessary pressure, you must fit
an applicable pressure adjuster on the gas sup-
ply pipe.
Adjustment of minimum level
To adjust the minimum level of the burners:
1. Light the burner.
2. Turn the knob on the minimum position.
3. Remove the knob.
4. With a thin screwdriver, adjust the by-pass
screw position.
A
A) The by-pass screw
If you change from natural gas G20 20 mbar
to liquid gas, fully tighten the adjustment
screw in.