38
11.2 Checking components for proper operation
To make it easier to check components, a TEST PROCEDURE has been developed which indicates the
points where tester probes should be applied and the correct theoretical value for each component.
Access the electronic board positioned on the basement and detach all the connectors.
Connect the probes of the tester to the appropriate points. Compare the electric resistance reading with
the value shown on the table
Measurement points on circuit board wiring connectors:
LIST OF COMPONENTS
PROBE
CONTACTS
CORRECT VALUES NOTES
LE1
0 Ω
* POWER CABLE &
(PU) - ON/OFF SWITCH
NE3
0 Ω
with ON/OFF button
pressed
(RR) - HEATING ELEMENT +
(TS) - SAFETY THERMOSTAT
E1E2
25 Ω ± 8%
connected in series
(2100W)
INFINITE
on EMPTY (1-2)
(PR) - LEVEL PRESSURE SWITCH
E1B1
0 Ω
on FULL (1-3)
INFINITE
on EMPTY (1-2)
(PA) - ANTI-FLOODING PRESSURE
SWITCH
B5E3
0 Ω
on FULL (1-3)
(IP) - DOOR MICROSWITCH
F1F3 on the
Input board
0 Ω
Door closed
(DD/DB) - INTEGRATED DISPENSER
A3A5
1500 Ω ± 8%
OK
INFINITE
with Rinse-aid
(SB) - RINSE-AID SENSOR
C1C3 on the
Output board
0 Ω
without Rinse-aid
INFINITE
with salt
(SS) - SALT SENSOR
H1H3
0 Ω
without salt
4850 Ω ± 5%
(at 25ºC)
(ST) - TEMPERATURE SENSOR
H7H8
1205 Ω ± 5%
(at 60ºC)
(GT) - TACHOMETRIC SENSOR
G1G2
210 Ω ± 8%
OK
(MV) - FAN MOTOR
D1D3
7750 Ω ± 8%
OK
(ER) - REGENERATION SOLENOID
F1F3
6K Ω ± 8%
OK
(EC) - FILL SOLENOID +
(AA) - ANTI-FLOODING DEVICE
A1A2
3800 Ω ± 8%
connected in series
F5F7
50 Ω ± 8%
start winding
(PL) - WASH MOTOR
To the two motor
wires (blue) / (red)
180 Ω ± 8%
auxiliary winding
(PS) - DRAIN MOTOR
B5F7
180 Ω ± 8%
OK
Note: - * = Measurement points L and N refer to the pins on the plug fitted to the power cable.
** = Fill in about 4l water so that the level pressure switch is on full position.