ble section is applicable to the voltage load and
the working temperature.
The wires in the cord are coloured as follows:
Green and yellow - Earth
Blue - Neutral
Brown - Live
1. Remove the mains terminal cover plate
from the bottom side of the hob to uncover
the mains terminal block.
2. Loosen the two cable clamp screws and lift
the top side of the clamp so the cable can
go through it.
3. Connect the green and yellow (earth) wire
to the terminal which is marked with the
number 5 or the letter 'E', or the earth sym-
bol
, or coloured green and yellow. (see
Figure 1)
4. Connect the blue (neutral) wire to the ter-
minal which is marked with the number 4
or the letter 'N' or coloured blue. (see Fig-
ure 1)
5. Connect the brown (live) wire to the termi-
nal which is marked with the number 1, the
letter 'L'. It must always be connected to
the network phase. (see Figure 1)
Figure 1
12345
There must be no cut or stray strands of wire
present. The cord clamp must be correctly at-
tached to the outer sheath.
Connection Min. size ca-
ble / flex
Fuse
Appliance control cir-
cuit
6 mm² 30 A
The yellow / green earth wire (B) must be
approximately 2 cm longer than the live
and neutral wire (A).
AB
6. Secure the cable by means of the clamp
screws and refit the terminal block cover.
Important! According to the current
regulations only a qualified electrician or
competent person can replace the mains cable.
Building In
min. 55 mm
min. 650 mm
560 mm
min. 450 mm
30 mm
470 mm
min. 600 mm
10 mm
11 mm
11 mm
A
3 mm
A
B
A) supplied seal
B) supplied brackets
10
www.zanussi.com