Make sure that there is an access to the
mains plug after installation.
Do not pull the mains cable to disconnect
the appliance. Always pull the mains plug.
The appliance must not be connected with
an extension cable, an adapter or a multiple
connection (risk of fire). Check that the
ground connection is in conformity with the
standard and regulations force.
The power cable must be placed in such a
way that it does not touch any hot part.
Connect the appliance to the mains with a
device that lets to disconnect the appliance
from the mains at all poles with a contact
opening width of minimum 3 mm, eg. auto-
matic line protecting cut-out, earth leakage
trips or fuse.
None of a parts of the connection cable can
not get a temperature 90°C. The blue neutral
cable must be connected to the terminal
block label with "N". The brown (or black)
phase cable (fitted in the terminal block con-
tact marked with "L") must always be con-
nected to the live phase.
Connection cable
Use only connection cable of type H05V2V2-F
T90 or equivalent type. Make sure that the ca-
ble section is applicable to the voltage and the
working temperature. The yellow/green earth
wire must be approximately 2 cm longer than
the brown (or black) phase wire.
Building In
min. 55 mm
min. 650 mm
560 mm
30 mm
480 mm
10 mm
11 mm
11 mm
A
3 mm
B
A
A) supplied seal
B) supplied brackets
Possibilities for insertion
Kitchen unit with door
The panel installed below the hob must be easy
to remove and let an easy access in case a
technical assistance intervention is necessary.
min 20 mm
(max 150 mm)
30 mm
60 mm
b
a
a) Removable panel
b) Space for connections
17