Zanussi ZEL640W Manual do Utilizador Página 10

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
Vista de página 9
Figure 1
L N
There must be no cut or stray strands of wire
present. The cord clamp must be correctly at-
tached to the outer sheath.
Connection Min. size
cable / flex
Fuse
Appliance control cir-
cuit
6 mm² 30 A
The yellow / green earth wire (B) must be
approximately 2 cm longer than the live
and neutral wire (A).
AB
6. Secure the cable by means of the clamp
screws and refit the terminal block cover.
Important! According to the current
regulations only a qualified electrician or
competent person can replace the mains
cable.
Assembly
min. 55 mm
min. 650 mm
550 mm
min. 100 mm
min. 600 mm
30 mm
470 mm
B
A
A) seal to remove
B) supplied brackets
Caution! Install the appliance only on a
worktop with flat surface.
Possibilities for insertion
Kitchen unit with door
The panel installed below the hob must be
easy to remove and let an easy access in case
a technical assistance intervention is necessa-
ry.
min 20 mm
(max 150 mm)
30 mm
60 mm
B
A
a) Removable panel
b) Space for connections
Kitchen unit with oven
The electrical connection of the hob and the
oven must be installed separately for safety
reasons and to let easy remove oven from the
unit.