OTHER TECHNICAL DATA
Appliance category: II2H3B/P
Gas original: G20 (2H) 20 mbar
Gas replacement: G30/G31 (3B/P) 30/30 mbar
BYPASS DIAMETERS
BURNER
Ø BYPASS
1)
1/100 mm
Auxiliary 29 / 30
Semi-rapid 32
Rapid 42
Oven 44
1) Type of bypass depends on model.
GAS BURNERS FOR NATURAL GAS G20 20 mbar
BURNER
NORMAL POWER
kW
1)
REDUCED POWER kW
1)
INJECTOR MARK
1/100 mm
Rapid 3.0 0.72 / 0.75 119
Semi-rapid 2.0 / 1.9 0.43 / 0.45 96
Auxiliary 1.0 0.35 70
Oven 2.7 0.90 120
Grill 1.9 - 108
1) Type of tap depends on model.
GAS BURNERS FOR LPG G30 30 mbar
BURNER
NORMAL POWER
kW
REDUCED POW-
ER kW
INJECTOR MARK
1/100 mm
NOMINAL GAS
FLOW g/h
Rapid 3.0 0.72 88 218
Semi-rapid 2.0 0.43 71 145
Auxiliary 1.0 0.35 50 73
Oven 2.7 0.90 80 196
Grill 1.9 - 71 138