1. Install the anti-tilt protection 317 - 322 mm
down from the top surface of the appliance and
80 - 85 mm from the side of the appliance into
the circular hole on a bracket. Screw it into the
solid material or use applicable reinforcement
(wall).
2. You can find the hole on the left side at the
back of the appliance. Lift the front of the
appliance and put it in the middle of the space
between the cupboards. If the space between
the bench cupboards is larger than the width of
the appliance, you must adjust the side
measurement to centre the appliance.
If you changed the dimensions of the
cooker, you must align the non-tip
device correctly.
CAUTION! If the space between the
bench cupboards is larger than the
width of the appliance, you must
adjust the side measurement to the
centre of the appliance.
ELECTRICAL INSTALLATION
WARNING! The manufacturer is not
responsible if you do not follow the
safety precautions from Safety
chapters.
This appliance is supplied without a main plug or a
main cable.
WARNING! Before you connect the
mains cable to the terminal, measure
the voltage between phases in the
house network. Then, refer to the
connection label at the back of the
appliance to use the correct electrical
installation. This order of steps
prevents from installation errors and
damage to the electrical components
of the appliance.
Applicable types of cables for different
phases:
Phase Min. size cable
1 3x6.0 mm²
3 with neutral 5x1.5 mm²
WARNING! The power cable must
not touch the part of the appliance
shaded in the illustration.
7