To prevent contact between the cable and the
appliance below the hob use the clamps which
are on the side of the cabinet.
A
A) Rigid copper pipe or flexible pipe of stain-
less steel
Replacement of the connection cable
To replace the connection cable use only
H05V2V2-F T90 or equivalent type. Make sure
that the cable section is applicable to the volt-
age and the working temperature. The yellow/
green earth wire must be approximately 2 cm
longer than the brown (or black) phase wire.
Building In
min. 55 mm
min. 650 mm
560 mm
min. 200 mm
30 mm
480 mm
10 mm
86 mm
86 mm
A
3 mm
B
A
A) supplied seal
B) supplied brackets
Caution! Install the appliance only on a
worktop with flat surface.
If you install the hob under a hood, please
see the installation instructions of the hood
for the minimum distance between the applian-
ces.
Possibilities for insertion
Kitchen unit with door
The panel installed below the hob must be easy
to remove and let an easy access in case a
technical assistance intervention is necessary.
min 20 mm
(max 150 mm)
30 mm
60 mm
B
A
A) Removable panel
B) Space for connections